PDA

View Full Version : LCD SERIES ERRORS AND FIX's THE FINAL THREAD


Shibbykins
10-23-2007, 02:27 PM
Most common questions im LCD forum: (Questions in RED)

My board says FAULT

Open your grip and press the 2 internal buttons to reset, if it keeps saying it then refer to the following list

Code 1 meant faulty battery but that can happen the first few charges or if you put in a new battery or the first few charges if the gun goes completely dead
Code 2 means the hopper is using too much power
Code 3 is temp is too high
Code 4 is temp is too low

if 3/4 are there see sticky about replacement boards HERE (http://www.angelowners.com/showthread.php?t=68309)

Board says PIN ERROR;

A. Send to a MT
B. Find someone with a datalink who will reset it.


MY board is locked how do I unlock it;

A. send to a MT
B. Find someone with a datalink who will unlock it.

Board says TEMP error

thermometer on the chipset is BAD and the board is junk. If that is you then see the sticky about replacement boards.

everytime i hook up the charger, the board says "tab in".

leave the chgr plugged in and make sure the switch is in the on position. sometimes after extended dead batteries it will do this,also it could indicate a broken wire on the switch

I took my angel apart yadda yadda and when i reconnected it and tried to fire i heard a clicking sound and marker would fire randomly

Ensure the solenoid plug is actually plugged into the solenoid port and not the hopper port.

I've got an *insert model*, and it won't hold a charge

Could just be a bad cell in the battery or your board or even charger are failing. Usually once this issue starts it is pretty much a done deal.

6v batterys arnt made anymore so go HERE (http://www.ballisticbatteries.com/Store_Detail.cfm?ID=110124&InfoID=200&ShowLarge=True) They make a aftermarket 6v for the angels and its very affordable.

can a G7/A4 NMHD 4.8v battery work in a 2000 - 2003 model LCD Angel?

the solinoid and board require a higher voltage to run it wouldnt work very well if at all.

see above link for the 6v Battery link

My pressures are all messed up what should they be set at

Air System 700-850psi
Minireg 450-500psi
LPR 86-90psi